Product Description-Available in custom size or standard 4' widths, these transparent curtain systems are made up of
a series of 8" wide strips clamped together at the top and suspended vertically. Ideal for containing noise to one side of an area where exit/entry is a must.Transparent, flexible vinyl strips
or sheets of acoustic barrier material used to "block" the transmission of sound in areas where noise abatement is a must, but visibility, passage, light, or temperature control is a must as well! Ideally
suited for window coverings, shipping and receiving doors, conveyers, room partitions and assembly lines. Also meets USDA requirements for use in food
processing locations! A good alternative to any sliding door in a QBS curtain enclosure, or where forklifts need entry/exit! Tips:
Remember that leakage occurs with the vertical strip setup. Therefore we double layer the material with a 100% overlap from the back layer to the front.
Use this material only where transparency or exit/entry is a must! Also ask NetWell about our stitching capabilities to sew this material into our
QBS-1 Blankets.
Installation Techniques:
You can create your own installation by securing firring strips to both sides of the top of the strips, and band them together, or have NetWell provide clamps cut in 4' widths.
Strip or solid clear vinyl curtains are mounted using either a Header Mount or Wall Mount Ssytem that is included with the order. The metal brackets are
designed to properly support the weight of the material and avoid potential tearing that standard grommets would cause. Standard widths of the mounting
hardware is 48", with 8" strips overlapped being secured with bolts to the mounting hardware. For more information contact your NetWell consultant at 1-800-NETWELL!
Physical Properties:
Thickness |
.08" |
Width |
8" wide strips with 100% overlap in 4' wide curtain. Custom widths also
available.) |
Weight |
I pound per square foot |
Tensile Strength |
2530 PSI |
Ultimate Elongation |
350% |
Tear Resistance |
291 pounds per square inch |
Fire Rating |
Meets Class A ASTM 84 requirements |
Operating Temperature |
-10 degrees to +140 degrees fahrenheit |
Test Results
Frequency (Hz) |
125 |
250 |
500 |
1000 |
2000 |
4000 |
AVG |
dB Loss (STC) |
8 |
13 |
17 |
22 |
27 |
31 |
20 |
Applications
- Forklift areas
- As doors in a QBS blanket enclosure
- Loading Dock areas
- Conveyer areas
- Assembly Lines
- Window Coverings
- Cooler / Freezers
- Machine Enclosures
- Outdoor Applications
- More!